分析コードの計算結果
警告: 結果はおおよそのものです, それは販売担当者とダブルチェックし材料を購入する前にインストールを検証することをお勧めします.
太陽光発電パネル
ここでは、電源を探しています (ピーク, W で表現) 太陽電池パネルからあなたの地理的な場所に応じてお客様のニーズを満たすためにマウントする. 式は以下の通りです :
Pp = Dn / (Yb X Yi X Rd)
- Pp (Wp) : Peak power (goal)
- Dn (Wh/d) : Daily needs = 240
- Yb : 電池の電気収穫 0.85
- Yi : electrical yield for the remaining installation (charge controller, ...) = 0.87
- Rd : パネルの平面の最も悪い月の平均毎日の放射 (kWh/m²/d)
- According to data from PVGIS, the value for the selected location is 0.95022 kWh/m²/d
あなたの場合、結果は :
プロセスを非表示にする
Pp = 240 / (0.85 * 0.87 * 0.95022) = 342 W
Photovoltaic panels produce electricity from sunlight (solar radiation).
According entered data, 342W of solar panel are required to fulfill your daily needs of 240Wh/d.
See, understand the procedure, the calculation
One possibility could be to have 1 panel(s) monocristalin of 360W each (?). Which extend the unit capacity to 360W
電池
We are looking here for the nominal capacity expressed in ampere per hour (Ah, given in C10)
Cap = (Dn x Aut) / (DD x U)
- Cap (Ah) : Nominal capacity of batteries (in C10))
- Dn (Wh/d) : Daily needs = 240
- Aut: Autonomous days amount (no sun) = 3
- DD (%) : 最大吐出率 = 30
- U (V) : 最終電池工場の電圧 = 12
あなたの場合、結果は :
プロセスを非表示にする
Cap = (240 x 3) / (0.3 x 12) = 200 Ah
Batteries are used to store electric energy produced by the panels. You will need a battery plant of 200 Ah at 12 V.
See, understand the procedure, the calculation
A wiring hypothesis would be to have 1> GEL 12V 250Ah type batteries, which increases the plant capacity up to 250Ah
Charge controller
充電コントローラは電池とパネルの間に立って、その役割は、パネルが提供できるものに応じて電池の充電を処理することです.
A wiring hypothesis would be to have a MPTT 250/65 type charge controller(?) on which would be connected 1 パネル
A type MPTT 250/65 charge controller, with a 12V battery plant, allows :
- 860W max panel power :
- With a total of 1 360W panel(s), we reach 360W (?)
- 250V max PV voltage of open circuit :
- With 1 serialized panel(s) of 47V of (Voc) voltage and a 20% security margin, we reach 56V (?)
- 30A max PV short-circuit current :
- With 1 parallel panel(s) having 10A intensity (Isc) and a 10% security margin, we reach 11A (?)
Note: serialization multiplies voltage (V) and paralleling multiplies the intensity (I)
これらの特性はすべて製品のテクニカルシートでご利用いただけます. では充電コントローラの特性をカスタマイズできます エクスポート モード.
プロセスの非表示
See, understand the process
Cable diagram
A wiring diagram was established according to panel/charge controller/battery hypothesis :
Converter
The converter goal is to transform batteries DC current (here 12V) in AC current usable for standard devices. You need a converter able to deliver the 10W max electric power you need.
An hypothesis would be to choose a 12/180 type converter that goes up to 175W max power with possible peaks at 350W.
バッテリ制御
It is recommended to have a bettery controleur in order to check battery plant charge state.
The wiring
Wire section choice ( calculate) is important in order to avoid electricity lossess :
- Between panels and charge controller, for a distance of 8m, a 6mm² section cable is recommended (see, understand the procedure)
プロセスの非表示
損失を避けるためにワイヤセクションを計算する数式は :
S = Rho x L x I / VL
- S (mm²) : Wire section
- Rho (ohm) : Wire resistivity (0,017ohm for copper)
- L (m) : back and forth wire length
- I (A): Intensity (here panel intensity multiplied by the number of parallel)
- VL (V) : 認められたワイヤーレベルの電圧損失 (1% 電圧の)
- (panels voltage * number of series) * 1/100
In our case it gives :
S = 0.019 x (8x2) x 10 / 0.47 = 6.47mm²
- Nearest wire section suggested : 10mm², approximate cost 16€
- Between charge controller and batteries, for a 1.5m distance, a wire section of 14.25mm² is recommended (see, understand the procedure)
Hide process
損失を避けるためにワイヤセクションを計算する数式は :
S = Rho x L x I / VL
- S (mm²) : Wire section
- Rho (ohm) : Wire resistivity (0,017ohm for copper)
- L (m) : back and forth wire length
- I (A): Intensity (here the power of the panels / the voltage of the battery bank)
- VL (V) : 認められたワイヤーレベルの電圧損失 (1% 電圧の)
- Batteries voltage, i. e. 12V * 1/100
In our case it gives :
S = 0.019 x (1x2) x (360 / 12) / 0.12 = 14.25mm²
- Nearest wire section suggested : 16mm², approximate cost 6€
Another and more complete wire section calculator is avalaible at sigma-tec.
予算
_('This is an approximate estimation for new equipment, it can\'t be considered as a quote.') ?>
- 太陽光発電パネル : between 234€ and 396€ (?)
- 電池 : between 540€ and 852€ (?)
- Charge controller : 約 700€
- Converter : between 70€ and 85€ (?)
- バッテリ制御 : 約 150€
- Wiring : 約 23€
Which brings to a total budget between 1717 and 2206€. Cost of panels support, wire, wire terminal and protection elements (fuse, battery cut-off, ...) is not included.
Support, contribute
If this software was helpfull and/or you want to thank :
This simulation estimates that with your consumption of 240Wh/d you would need:
- ~342W panel (1"330W for example)
- ~200Ah battery in 12V (1"250Ah in 12V for example)
The budget estimated between 1717 and 2206€
[url=http://calcpv.net/ja?Ni=2&Bj=240&Pmax=10&lat=46.69316&lon=6.727678&Ej=&inclinaison=0&orientation=0&periode=complete&periodeDebut=5&periodeFin=9&ModPv=auto&TypePv=monocristalin&PersoPvW=&PersoPvVdoc=&PersoPvIsc=&Rb=0.85&Ri=0.87&Aut=3&U=0&DD=30&ModBat=auto&TypeBat=auto&PersoBatAh=&PersoBatV=12&IbatCharge=20&IbatDecharge=20&ModRegu=auto&PersoReguPmaxPv=&PersoReguVmaxPv=&PersoReguImaxPv=®uMargeIsc=10®uMargeVoc=20&distancePvRegu=8&distanceReguBat=1.5&cablageRho=0.019&cablagePtPourcent=1&cablageRegleAparMm=6&submit=Lancer+le+calcul]This simulation[url] estimates that with your consumption of 240Wh/d you would need:
[list][*]~342W panel (1"330W for example)
[*]~200Ah battery in 12V (1"250Ah in 12V for example)[/list]The budget estimated between 1717 and 2206€